The Rishabh CQ Series consists of analog power factor meters designed to monitor power factor conditions in both balanced and unbalanced load systems . These meters indirectly determine the power factor by measuring the phase angle between sinusoidal current and voltage, displaying the results in values of pf/ph .
Measurement Range : Standard measuring ranges include -0.5 to +0.5 .
Accuracy : The meters have an accuracy class of 1.5 according to IS:1248 and IEC 51 standards .
Design : The instruments feature a knife-edge pointer and a non-linear scale division . The housing is made of flame-retardant, glass-filled polycarbonate .
Mounting : They support mosaic mounting, allowing multiple meters to be installed in a single cutout .
Overload Capacity : Capable of handling 1.2 times the rated voltage/current continuously, and up to 10 times the rated current for a maximum of 5 seconds .
Categories: Meters, Relays, Timers, Counters, APFC
Physical Specifications
The CQ series is available in three standard sizes:
Safety and Environmental Compliance